Figure 5. The viral load during the early stages of infection inversely correlated with the level of high-avidity SHIV-specific CD8+CTLs in the mucosal lymphoid tissues but not in blood. (A) Dynamics of the relationships between log viral load in blood on day 17 and avidity of the CL10-specific CTLs (against target cells pulsed with 10 μM, 1 μM, 0.1 μM, and 0.01 μM peptide) in MLNs before SHIV challenge. Individual data points for macaques in group 1 are color-coded as red squares; group 2, green diamonds; and group 3, blue circles. Spearman correlation coefficient and its P value were calculated. (B) Dynamics of correlation between high-avidity (0.001 μM), intermediate-avidity (1 μM), or low-avidity (10 μM) CL10-specific responses and log plasma viral load over time. The dynamics of high-avidity (0.001 μM) CTLs were significantly different from those of the CTLs measured at 1 and 10 μM peptide (P < .001). All correlation coefficients were negative (inverse correlation), but those with absolute value < 0.5 were not significant (above the horizontal line). (C) Correlation between high- and intermediate-avidity (0.1 μM and 1 μM) Gag372-specific responses before viral challenge and log of plasma viral load on day 17.
Figure 5.

The viral load during the early stages of infection inversely correlated with the level of high-avidity SHIV-specific CD8+CTLs in the mucosal lymphoid tissues but not in blood. (A) Dynamics of the relationships between log viral load in blood on day 17 and avidity of the CL10-specific CTLs (against target cells pulsed with 10 μM, 1 μM, 0.1 μM, and 0.01 μM peptide) in MLNs before SHIV challenge. Individual data points for macaques in group 1 are color-coded as red squares; group 2, green diamonds; and group 3, blue circles. Spearman correlation coefficient and its P value were calculated. (B) Dynamics of correlation between high-avidity (0.001 μM), intermediate-avidity (1 μM), or low-avidity (10 μM) CL10-specific responses and log plasma viral load over time. The dynamics of high-avidity (0.001 μM) CTLs were significantly different from those of the CTLs measured at 1 and 10 μM peptide (P < .001). All correlation coefficients were negative (inverse correlation), but those with absolute value < 0.5 were not significant (above the horizontal line). (C) Correlation between high- and intermediate-avidity (0.1 μM and 1 μM) Gag372-specific responses before viral challenge and log of plasma viral load on day 17.

or Create an Account

Close Modal
Close Modal